Expert HVAC & Plumbing in Elkhart, IN | Church Plumbing
24/7 Emergency Service
Don’t let plumbing or HVAC issues interrupt your productivity. Get fast solutions with Church Plumbing & Heating, your local experts for Elkhart, South Bend and the surrounding areas. Call us today at (574) 205-9289 for immediate service.

Expert Plumbing, Heating & HVAC Services in Elkhart, IN

Close Up Of Worker Fixing Central Heating Furnace System.

In Elkhart, Indiana, where winter mornings bite and summer humidity lingers, your home’s plumbing and HVAC systems aren’t luxuries. They’re lifelines. At Church Plumbing & Heating, Inc., we deliver fast, honest, and dependable home services that keep Elkhart homes running smoothly in every season. Whether you’re dealing with a backed-up sewer line, a worn-out water heater, or an AC that can’t keep up, we’ll show up, assess the problem, and fix it with precision and care.

Our commitment goes beyond tools and truck rolls. We build trust with every service call through clear communication, fair pricing, and work we’re proud to stand behind. Call Church today at (574) 205-9289 or schedule your service online, because in a city like Elkhart—known for its hardworking people, deep roots, and Midwest pride—you deserve a local team that truly has your back.

Local HVAC & Plumbing Service Backed by Community Trust

Elkhart is more than an RV capital. It’s a city of craftsmen, teachers, entrepreneurs, and everyday families. From neighborhood hangouts in the Riverwalk district to peaceful mornings on the St. Joseph River, Elkhart is a blend of history, progress, and small-town pride. It’s also a place where homes range from historic gems to new construction—all of which face the full brunt of Indiana’s unpredictable climate.

At Church Plumbing & Heating, we know what that means. We tailor every repair, installation, and tune-up to meet the unique needs of your home. Our team lives here, works here, and takes real pride in delivering service that reflects the values of the community we’re honored to serve.

Schedule your Appointment Today!

(574) 205-9289

Professional Air Conditioning Repair in Elkhart, IN

Summers in Elkhart can be sticky and sweltering. If your air conditioning system isn’t up to the task, we’re ready to step in. From minor repairs to full AC replacements, we help you beat the heat with expert service and energy-efficient solutions.

Heating Repair That Keep You Cozy in Elkhart Winters

When Elkhart temperatures drop into the single digits, a dependable heating system isn’t optional—it’s essential. We offer repairs, replacements, and preventive maintenance to ensure your home stays warm when it matters most.

Expert Plumbing Repair for Elkhart Homes

Real Plumber at work under a sink

From quiet leaks to full-blown plumbing emergencies, we provide residential plumbing services that get to the root of the problem. No mess, no guesswork—just reliable solutions from skilled professionals.

Water Heater Installation & Repair in Elkhart

Running out of hot water isn’t just inconvenient—it can derail your entire routine. From cold morning showers to dishes that won’t rinse clean, it’s a hassle no homeowner should have to deal with. At Church Plumbing & Heating, we provide professional water heater services to keep your home comfortable and functional. Whether you’re upgrading to a tankless system, replacing an old unit, or just need a quick repair, we help Elkhart families stay warm, energy-efficient, and confident their hot water is ready when they need it.

Schedule your Appointment Today!

(574) 205-9289

Why Elkhart Chooses Church Plumbing & Heating

We’ve built our reputation the same way Elkhart has grown—through hard work, local pride, and a commitment to doing things right. For decades, families across Elkhart have trusted Church Plumbing & Heating not just because of what we fix, but how we treat every customer along the way. Our service is more than technical expertise—it’s about integrity, reliability, and community connection.

  • Clear, honest service with no surprises: We communicate openly and recommend only what you truly need.
  • Respectful, punctual professionals: Our technicians arrive on time, in uniform, and treat your home with care.
  • Quality workmanship that lasts: We stand by our repairs and installations with strong warranties and a satisfaction guarantee.
  • Available when you need us most: Our 24/7 emergency response means you’ll never face a crisis alone.
  • Local, friendly service with heart: We’re not just service providers—we’re neighbors who care about your comfort.

Book Trusted Plumbing or HVAC Services in Elkhart Today

At Church Plumbing & Heating, Inc., we’re not here for quick fixes or one-time visits—we’re here to be your go-to home service partner in Elkhart, Indiana. From high-efficiency HVAC upgrades to plumbing repairs that hold up, we’re committed to doing the job right the first time.

Reach out to us today by calling (574) 205-9289 or schedule your service online. Let us bring comfort, reliability, and real peace of mind to your home—one solution at a time.

 

Recent Jobs and Reviews in Elkhart, IN

Job Locations and Reviews

Completed pressure test on central heating system as follow-up to previous service work. Accessed property using company keys with customer authorization. Inspected plumbing fixtures including basement main valve and toilet supply lines. No active leaks detected during visual inspection. Documented existing conditions including mineral deposits and rust staining observed in toilet tank components. System holding pressure satisfactorily with no new issues identified following recent water service restoration by municipality.
Completed pressure test on central heating system as follow-up to previous service work. Accessed property using company keys with customer authorization. Inspected plumbing fixtures including basement main valve and toilet supply lines. No active leaks detected during visual inspection. Documented existing conditions including mineral deposits and rust staining observed in toilet tank components. System holding pressure satisfactorily with no new issues identified following recent water service restoration by municipality.
Kristi P.
Kristi P. Checked in
Completed pressure test on central heating system as follow-up to previous service work. Accessed property using company keys with customer authorization. Inspected plumbing fixtures including basement main valve and toilet supply lines. No active leaks detected during visual inspection. Documented existing conditions including mineral deposits and rust staining observed in toilet tank components. System holding pressure satisfactorily with no new issues identified following recent water service restoration by municipality.
Elkhart, IN 46514
Provided comprehensive plumbing estimate for residential property including interior water line connections, dishwasher drainage installation, and exterior hose bibb replacement. Assessed existing plumbing infrastructure at exterior wall penetrations and interior bathroom fixtures to determine scope of work for complete water supply hookup and drainage system modifications.
Provided comprehensive plumbing estimate for residential property including interior water line connections, dishwasher drainage installation, and exterior hose bibb replacement. Assessed existing plumbing infrastructure at exterior wall penetrations and interior bathroom fixtures to determine scope of work for complete water supply hookup and drainage system modifications.
Michael C.
Michael C. Checked in
Provided comprehensive plumbing estimate for residential property including interior water line connections, dishwasher drainage installation, and exterior hose bibb replacement. Assessed existing plumbing infrastructure at exterior wall penetrations and interior bathroom fixtures to determine scope of work for complete water supply hookup and drainage system modifications.
Elkhart, IN 46514
Elkhart, IN - Responded to no cooling complaint on an 8-year-old residential air conditioning system with airflow present but inadequate cooling. Performed diagnostic evaluation of the outdoor condensing unit and associated refrigerant lines. Documented equipment condition and installation configuration for service records.
Dave M.
Dave M. Checked in
Responded to no cooling complaint on an 8-year-old residential air conditioning system with airflow present but inadequate cooling. Performed diagnostic evaluation of the outdoor condensing unit and associated refrigerant lines. Documented equipment condition and installation configuration for service records.
Elkhart, IN 46516
Responded to service call for slow-flushing toilet in secondary restroom. Performed diagnostic inspection of toilet tank components, including flush valve assembly, fill valve, and float mechanism. Assessed internal flushing system operation and identified potential issues affecting flush performance.
Responded to service call for slow-flushing toilet in secondary restroom. Performed diagnostic inspection of toilet tank components, including flush valve assembly, fill valve, and float mechanism. Assessed internal flushing system operation and identified potential issues affecting flush performance.
Kristi P.
Kristi P. Checked in
Responded to service call for slow-flushing toilet in secondary restroom. Performed diagnostic inspection of toilet tank components, including flush valve assembly, fill valve, and float mechanism. Assessed internal flushing system operation and identified potential issues affecting flush performance.
Elkhart, IN 46517
Responded to water leak emergency in basement area near water heater with standing water present on concrete floor. Upon arrival, water supply was already shut off by customer. Conducted thorough inspection of water heater installation, associated copper supply lines, PVC drainage system, and all visible plumbing connections including shutoff valves and brass fittings. Examined mounting brackets, rubber couplings, and mechanical systems in utility area to identify source of leak causing dark discoloration on cement floor. Documented existing conditions of water heater unit, flexible gas connector line, drainage pipes, and surrounding plumbing infrastructure through photographic evidence for diagnostic purposes.
Responded to water leak emergency in basement area near water heater with standing water present on concrete floor. Upon arrival, water supply was already shut off by customer. Conducted thorough inspection of water heater installation, associated copper supply lines, PVC drainage system, and all visible plumbing connections including shutoff valves and brass fittings. Examined mounting brackets, rubber couplings, and mechanical systems in utility area to identify source of leak causing dark discoloration on cement floor. Documented existing conditions of water heater unit, flexible gas connector line, drainage pipes, and surrounding plumbing infrastructure through photographic evidence for diagnostic purposes.
Greg K.
Greg K. Checked in
Responded to water leak emergency in basement area near water heater with standing water present on concrete floor. Upon arrival, water supply was already shut off by customer. Conducted thorough inspection of water heater installation, associated copper supply lines, PVC drainage system, and all visible plumbing connections including shutoff valves and brass fittings. Examined mounting brackets, rubber couplings, and mechanical systems in utility area to identify source of leak causing dark discoloration on cement floor. Documented existing conditions of water heater unit, flexible gas connector line, drainage pipes, and surrounding plumbing infrastructure through photographic evidence for diagnostic purposes.
Elkhart, IN 46514
Conducted site assessment for commercial building currently without heating or cooling system. Evaluated electrical infrastructure and existing conditions to determine feasibility of installing new HVAC system. Documented electrical panel capacity and configuration, assessed available space for equipment installation, and reviewed structural considerations for AC and furnace installation. Provided customer with multiple equipment options including commercial-grade systems based on building requirements and discussed financing availability.
Conducted site assessment for commercial building currently without heating or cooling system. Evaluated electrical infrastructure and existing conditions to determine feasibility of installing new HVAC system. Documented electrical panel capacity and configuration, assessed available space for equipment installation, and reviewed structural considerations for AC and furnace installation. Provided customer with multiple equipment options including commercial-grade systems based on building requirements and discussed financing availability.
Michael C.
Michael C. Checked in
Conducted site assessment for commercial building currently without heating or cooling system. Evaluated electrical infrastructure and existing conditions to determine feasibility of installing new HVAC system. Documented electrical panel capacity and configuration, assessed available space for equipment installation, and reviewed structural considerations for AC and furnace installation. Provided customer with multiple equipment options including commercial-grade systems based on building requirements and discussed financing availability.
Elkhart, IN 46517
Completed toilet rebuild in commercial restroom facility. Removed existing tank components and installed new fill valve, flush valve assembly with red float mechanism, and flapper. Replaced corroded water supply shut-off valve with new fixture. Reset toilet with new wax ring seal to ensure proper connection to waste line. Tank interior showed significant age-related deterioration including rust staining and mineral deposits, which were addressed during component replacement. All internal mechanisms tested and verified operational upon completion.
Completed toilet rebuild in commercial restroom facility. Removed existing tank components and installed new fill valve, flush valve assembly with red float mechanism, and flapper. Replaced corroded water supply shut-off valve with new fixture. Reset toilet with new wax ring seal to ensure proper connection to waste line. Tank interior showed significant age-related deterioration including rust staining and mineral deposits, which were addressed during component replacement. All internal mechanisms tested and verified operational upon completion.
Kristi P.
Kristi P. Checked in
Completed toilet rebuild in commercial restroom facility. Removed existing tank components and installed new fill valve, flush valve assembly with red float mechanism, and flapper. Replaced corroded water supply shut-off valve with new fixture. Reset toilet with new wax ring seal to ensure proper connection to waste line. Tank interior showed significant age-related deterioration including rust staining and mineral deposits, which were addressed during component replacement. All internal mechanisms tested and verified operational upon completion.
Elkhart, IN 46514
Completed water softener replacement per approved quote in basement utility area. Performed preventive maintenance tune-up on furnace system, including filter inspection and operational testing. Installed equipment connects to existing PEX manifold distribution system serving radiant heating zones. All components secured to structural supports with proper clearances maintained for code compliance and future serviceability. System tested and operational upon completion.
Completed water softener replacement per approved quote in basement utility area. Performed preventive maintenance tune-up on furnace system, including filter inspection and operational testing. Installed equipment connects to existing PEX manifold distribution system serving radiant heating zones. All components secured to structural supports with proper clearances maintained for code compliance and future serviceability. System tested and operational upon completion.
Greg K.
Greg K. Checked in
Completed water softener replacement per approved quote in basement utility area. Performed preventive maintenance tune-up on furnace system, including filter inspection and operational testing. Installed equipment connects to existing PEX manifold distribution system serving radiant heating zones. All components secured to structural supports with proper clearances maintained for code compliance and future serviceability. System tested and operational upon completion.
Elkhart, IN 46517
Conducted on-site assessment for shower installation project in downstairs bathroom. Evaluated existing bathroom layout featuring basket-weave tile flooring, mint green walls, and standard toilet fixture to determine optimal placement for new shower unit with surround. Documented current bathroom dimensions and configuration in narrow residential layout. Inspected basement ceiling area below bathroom to assess existing plumbing infrastructure, including white PVC drain lines, black waste pipes, and P-trap assembly. Identified accessible joists and framing for potential shower drain connection and water supply routing. Photographed exposed plumbing system and structural framing to develop accurate material list and labor estimate for complete shower installation with surround panels.
Conducted on-site assessment for shower installation project in downstairs bathroom. Evaluated existing bathroom layout featuring basket-weave tile flooring, mint green walls, and standard toilet fixture to determine optimal placement for new shower unit with surround. Documented current bathroom dimensions and configuration in narrow residential layout. Inspected basement ceiling area below bathroom to assess existing plumbing infrastructure, including white PVC drain lines, black waste pipes, and P-trap assembly. Identified accessible joists and framing for potential shower drain connection and water supply routing. Photographed exposed plumbing system and structural framing to develop accurate material list and labor estimate for complete shower installation with surround panels.
Noah L.
Noah L. Checked in
Conducted on-site assessment for shower installation project in downstairs bathroom. Evaluated existing bathroom layout featuring basket-weave tile flooring, mint green walls, and standard toilet fixture to determine optimal placement for new shower unit with surround. Documented current bathroom dimensions and configuration in narrow residential layout. Inspected basement ceiling area below bathroom to assess existing plumbing infrastructure, including white PVC drain lines, black waste pipes, and P-trap assembly. Identified accessible joists and framing for potential shower drain connection and water supply routing. Photographed exposed plumbing system and structural framing to develop accurate material list and labor estimate for complete shower installation with surround panels.
Elkhart, IN 46514
Replaced existing water heater with a new 40-gallon short A.O. Smith natural draft residential tank unit, model GCRL-40. Installed a shut-off valve on the cold water supply line to provide proper isolation capability for future maintenance and emergency shutdowns.
Replaced existing water heater with a new 40-gallon short A.O. Smith natural draft residential tank unit, model GCRL-40. Installed a shut-off valve on the cold water supply line to provide proper isolation capability for future maintenance and emergency shutdowns.
Kristi P.
Kristi P. Checked in
Replaced existing water heater with a new 40-gallon short A.O. Smith natural draft residential tank unit, model GCRL-40. Installed a shut-off valve on the cold water supply line to provide proper isolation capability for future maintenance and emergency shutdowns.
Elkhart, IN 46514
Responded to service call for three leaking faucets in the residence. Inspected and serviced two Delta brand faucets—one two-handle chrome faucet on beige countertop with integrated basin in bathroom, and one two-handle chrome faucet on white sink. Diagnosed worn internal components causing leaks, replaced cartridges and seals on all three faucet assemblies, and tested for proper operation and complete leak elimination.
Responded to service call for three leaking faucets in the residence. Inspected and serviced two Delta brand faucets—one two-handle chrome faucet on beige countertop with integrated basin in bathroom, and one two-handle chrome faucet on white sink. Diagnosed worn internal components causing leaks, replaced cartridges and seals on all three faucet assemblies, and tested for proper operation and complete leak elimination.
Greg K.
Greg K. Checked in
Responded to service call for three leaking faucets in the residence. Inspected and serviced two Delta brand faucets—one two-handle chrome faucet on beige countertop with integrated basin in bathroom, and one two-handle chrome faucet on white sink. Diagnosed worn internal components causing leaks, replaced cartridges and seals on all three faucet assemblies, and tested for proper operation and complete leak elimination.
Elkhart, IN 46514
Completed full HVAC system installation including ML196UH090 furnace (S#1725C18782), ML13KC1-042 condenser unit, CK40CT-36C coil, and associated components pulled from inventory. Extended gas line to ceiling using black pipe with elbow fitting, cut back existing OmegaFlex, and reconnected. System commissioned with refrigerant charge verified, all connections tested and confirmed operational.
Completed full HVAC system installation including ML196UH090 furnace (S#1725C18782), ML13KC1-042 condenser unit, CK40CT-36C coil, and associated components pulled from inventory. Extended gas line to ceiling using black pipe with elbow fitting, cut back existing OmegaFlex, and reconnected. System commissioned with refrigerant charge verified, all connections tested and confirmed operational.
Steven C.
Steven C. Checked in
Completed full HVAC system installation including ML196UH090 furnace (S#1725C18782), ML13KC1-042 condenser unit, CK40CT-36C coil, and associated components pulled from inventory. Extended gas line to ceiling using black pipe with elbow fitting, cut back existing OmegaFlex, and reconnected. System commissioned with refrigerant charge verified, all connections tested and confirmed operational.
Elkhart, IN 46514
Completed gas line installation in basement utility area per quoted specifications. Picked up necessary fittings and ran new black iron gas piping along ceiling joists, properly secured to existing structure with appropriate mounting hardware. All connections made to code with proper routing through unfinished basement space, terminating at designated appliance locations including water heater area.
Completed gas line installation in basement utility area per quoted specifications. Picked up necessary fittings and ran new black iron gas piping along ceiling joists, properly secured to existing structure with appropriate mounting hardware. All connections made to code with proper routing through unfinished basement space, terminating at designated appliance locations including water heater area.
Mark B.
Mark B. Checked in
Completed gas line installation in basement utility area per quoted specifications. Picked up necessary fittings and ran new black iron gas piping along ceiling joists, properly secured to existing structure with appropriate mounting hardware. All connections made to code with proper routing through unfinished basement space, terminating at designated appliance locations including water heater area.
Elkhart, IN 46517
Responded to water leak in lower level basement utility area. Upon arrival, identified active leak from damaged pipe connected to water heater with customer-placed bucket collecting water. Inspected water heater plumbing assembly including copper supply lines, PEX distribution lines, and associated fittings. Documented compromised pipe section with hole causing water discharge. Assessed surrounding plumbing infrastructure including PVC drainage system, gas connections, and mounting hardware for additional concerns. Photographed affected area showing water heater, furnace, and complete piping configuration for repair documentation and customer records.
Responded to water leak in lower level basement utility area. Upon arrival, identified active leak from damaged pipe connected to water heater with customer-placed bucket collecting water. Inspected water heater plumbing assembly including copper supply lines, PEX distribution lines, and associated fittings. Documented compromised pipe section with hole causing water discharge. Assessed surrounding plumbing infrastructure including PVC drainage system, gas connections, and mounting hardware for additional concerns. Photographed affected area showing water heater, furnace, and complete piping configuration for repair documentation and customer records.
Kristi P.
Kristi P. Checked in
Responded to water leak in lower level basement utility area. Upon arrival, identified active leak from damaged pipe connected to water heater with customer-placed bucket collecting water. Inspected water heater plumbing assembly including copper supply lines, PEX distribution lines, and associated fittings. Documented compromised pipe section with hole causing water discharge. Assessed surrounding plumbing infrastructure including PVC drainage system, gas connections, and mounting hardware for additional concerns. Photographed affected area showing water heater, furnace, and complete piping configuration for repair documentation and customer records.
Elkhart, IN 46514
Responded to service call for 7-year-old tanked water heater with reported water leakage from bottom of unit and inoperative pilot light with no status light indication. Upon arrival, performed comprehensive diagnostic inspection of gas control valve, burner assembly, and tank integrity. Removed access panel to examine internal components including gas control valve with status light indicator, flexible gas line connector, and burner assembly with brass fittings and copper connections. Inspected expansion tank mounted on top of unit with flexible braided hoses and brass fittings, along with associated copper piping and PVC connections running to ceiling joists. Identified active leak originating from lower tank section and confirmed pilot light failure with non-functional status indicator on gas control valve. Assessed overall system configuration including plumbing connections, gas supply line, and venting arrangement. Documented conditions through photographic evidence showing compro
Responded to service call for 7-year-old tanked water heater with reported water leakage from bottom of unit and inoperative pilot light with no status light indication. Upon arrival, performed comprehensive diagnostic inspection of gas control valve, burner assembly, and tank integrity. Removed access panel to examine internal components including gas control valve with status light indicator, flexible gas line connector, and burner assembly with brass fittings and copper connections. Inspected expansion tank mounted on top of unit with flexible braided hoses and brass fittings, along with associated copper piping and PVC connections running to ceiling joists. Identified active leak originating from lower tank section and confirmed pilot light failure with non-functional status indicator on gas control valve. Assessed overall system configuration including plumbing connections, gas supply line, and venting arrangement. Documented conditions through photographic evidence showing compro
Kristi P.
Kristi P. Checked in
Responded to service call for 7-year-old tanked water heater with reported water leakage from bottom of unit and inoperative pilot light with no status light indication. Upon arrival, performed comprehensive diagnostic inspection of gas control valve, burner assembly, and tank integrity. Removed access panel to examine internal components including gas control valve with status light indicator, flexible gas line connector, and burner assembly with brass fittings and copper connections. Inspected expansion tank mounted on top of unit with flexible braided hoses and brass fittings, along with associated copper piping and PVC connections running to ceiling joists. Identified active leak originating from lower tank section and confirmed pilot light failure with non-functional status indicator on gas control valve. Assessed overall system configuration including plumbing connections, gas supply line, and venting arrangement. Documented conditions through photographic evidence showing compro
Elkhart, IN 46514
Replaced leaking rear outdoor hose bib with new frost-free sillcock and installed interior shutoff valve on copper supply line in basement. Removed old corroded spigot from exterior wall, prepared mounting surface, and secured new unit with proper pitch for drainage. Inside the structure, cut into existing copper water line, installed compression shutoff valve with brass fittings to allow seasonal isolation of exterior fixture, and pressure tested all connections to verify leak-free operation.
Replaced leaking rear outdoor hose bib with new frost-free sillcock and installed interior shutoff valve on copper supply line in basement. Removed old corroded spigot from exterior wall, prepared mounting surface, and secured new unit with proper pitch for drainage. Inside the structure, cut into existing copper water line, installed compression shutoff valve with brass fittings to allow seasonal isolation of exterior fixture, and pressure tested all connections to verify leak-free operation.
Kristi P.
Kristi P. Checked in
Replaced leaking rear outdoor hose bib with new frost-free sillcock and installed interior shutoff valve on copper supply line in basement. Removed old corroded spigot from exterior wall, prepared mounting surface, and secured new unit with proper pitch for drainage. Inside the structure, cut into existing copper water line, installed compression shutoff valve with brass fittings to allow seasonal isolation of exterior fixture, and pressure tested all connections to verify leak-free operation.
Elkhart, IN 46516
Elkhart, IN - Responded to service call for 8-year-old tanked water heater with pilot light failure following recent drain and flush by homeowner. Performed diagnostic inspection of gas control valve, thermocouple, and pilot assembly to determine cause of ignition system malfunction. Completed necessary repairs to restore proper pilot light operation and verified unit returned to normal heating function.
Greg K.
Greg K. Checked in
Responded to service call for 8-year-old tanked water heater with pilot light failure following recent drain and flush by homeowner. Performed diagnostic inspection of gas control valve, thermocouple, and pilot assembly to determine cause of ignition system malfunction. Completed necessary repairs to restore proper pilot light operation and verified unit returned to normal heating function.
Elkhart, IN 46514
Responded to service call for 7-year-old Culligan water softener not consuming salt properly, indicating system malfunction. Performed comprehensive inspection of water treatment system in basement mechanical room, examining twin water softener tanks with blue control valves and associated plumbing connections. Assessed unit operation, control valve functionality, salt bridge formation, and brine tank operation to diagnose cause of improper regeneration cycle.
Responded to service call for 7-year-old Culligan water softener not consuming salt properly, indicating system malfunction. Performed comprehensive inspection of water treatment system in basement mechanical room, examining twin water softener tanks with blue control valves and associated plumbing connections. Assessed unit operation, control valve functionality, salt bridge formation, and brine tank operation to diagnose cause of improper regeneration cycle.
Greg K.
Greg K. Checked in
Responded to service call for 7-year-old Culligan water softener not consuming salt properly, indicating system malfunction. Performed comprehensive inspection of water treatment system in basement mechanical room, examining twin water softener tanks with blue control valves and associated plumbing connections. Assessed unit operation, control valve functionality, salt bridge formation, and brine tank operation to diagnose cause of improper regeneration cycle.
Elkhart, IN 46514
Elkhart, IN - Responded to no-cool complaint on upstairs unit at commercial facility with multiple HVAC systems. Upon arrival, found thermostat set to 70 degrees with space temperature reading 85 degrees and minimal airflow at registers. Performed diagnostic evaluation of outdoor condensing unit and indoor air handler. Inspected condenser unit located on exterior concrete pad with rock landscaping, confirmed unit over 10 years old. Tested electrical components, refrigerant pressures, and blower motor operation. Identified failed compressor with no amp draw and weak capacitor readings. Noted moisture accumulation on condenser pad indicating previous drainage issues. Checked indoor evaporator coil for restrictions and verified filter was changed recently with no blockages present. Presented repair options including compressor replacement versus full system replacement given age of equipment. Recommended system replacement due to unit age exceeding manufacturer's expected service life and declining eff
Mark B.
Mark B. Checked in
Responded to no-cool complaint on upstairs unit at commercial facility with multiple HVAC systems. Upon arrival, found thermostat set to 70 degrees with space temperature reading 85 degrees and minimal airflow at registers. Performed diagnostic evaluation of outdoor condensing unit and indoor air handler. Inspected condenser unit located on exterior concrete pad with rock landscaping, confirmed unit over 10 years old. Tested electrical components, refrigerant pressures, and blower motor operation. Identified failed compressor with no amp draw and weak capacitor readings. Noted moisture accumulation on condenser pad indicating previous drainage issues. Checked indoor evaporator coil for restrictions and verified filter was changed recently with no blockages present. Presented repair options including compressor replacement versus full system replacement given age of equipment. Recommended system replacement due to unit age exceeding manufacturer's expected service life and declining eff
Elkhart, IN 46514
Responded to service call for leaking outdoor water spigot located near building foundation. Upon arrival, inspected exterior hose bib assembly and main water shutoff valve positioned at ground level against exterior wall. Valve assembly showed significant weathering, corrosion, and patina consistent with age and prolonged outdoor exposure. Identified leak source at spigot connection point. Replaced defective outdoor spigot with new frost-free hose bib assembly. Tested system for proper operation and verified no additional leaks present at valve stem or shutoff assembly. System restored to full functionality.
Responded to service call for leaking outdoor water spigot located near building foundation. Upon arrival, inspected exterior hose bib assembly and main water shutoff valve positioned at ground level against exterior wall. Valve assembly showed significant weathering, corrosion, and patina consistent with age and prolonged outdoor exposure. Identified leak source at spigot connection point. Replaced defective outdoor spigot with new frost-free hose bib assembly. Tested system for proper operation and verified no additional leaks present at valve stem or shutoff assembly. System restored to full functionality.
Kristi P.
Kristi P. Checked in
Responded to service call for leaking outdoor water spigot located near building foundation. Upon arrival, inspected exterior hose bib assembly and main water shutoff valve positioned at ground level against exterior wall. Valve assembly showed significant weathering, corrosion, and patina consistent with age and prolonged outdoor exposure. Identified leak source at spigot connection point. Replaced defective outdoor spigot with new frost-free hose bib assembly. Tested system for proper operation and verified no additional leaks present at valve stem or shutoff assembly. System restored to full functionality.
Elkhart, IN 46514

 

What To Expect

Discover the Difference

Local People in Local Office

As a local company, we understand the HVAC and plumbing needs of our community. Our professionals are committed to bringing our neighbors the top-rated services they deserve.

Upfront Pricing & Quotes

We will provide you with an honest and accurate quote on every job and free estimates on replacements, so you won’t have to worry about running the bill up no matter how long the job takes.

Enhanced Labor Coverage

You can rest easy when you work with our team because we offer up to 5 years of enhanced labor coverage on repairs and up to 10 years on replacements.

24/7 Emergency Service

Sometimes issues arise outside of regular business hours. We’ve got you covered no matter what time your breakdown occurs. Our technicians are on call 24-hours a day, 365 days a year.

Friendly Technicians

Church technicians are the best and brightest professionals around. We always provide service with a smile, and many of our technicians have received NATE certifications.

Nationally Recognized

As an American Standard Dealer of The Year Winner, you can always count on the Church team to provide high-quality service and dependable solutions.

Local People in Local Office

As a local company, we understand the HVAC and plumbing needs of our community. Our professionals are committed to bringing our neighbors the top-rated services they deserve.

Upfront Pricing & Quotes

We will provide you with an honest and accurate quote on every job and free estimates on replacements, so you won’t have to worry about running the bill up no matter how long the job takes.

Enhanced Labor Coverage

You can rest easy when you work with our team because we offer up to 5 years of enhanced labor coverage on repairs and up to 10 years on replacements.

24/7 Emergency Service

Sometimes issues arise outside of regular business hours. We’ve got you covered no matter what time your breakdown occurs. Our technicians are on call 24-hours a day, 365 days a year.

Friendly Technicians

Church technicians are the best and brightest professionals around. We always provide service with a smile, and many of our technicians have received NATE certifications.

Nationally Recognized

As an American Standard Dealer of The Year Winner, you can always count on the Church team to provide high-quality service and dependable solutions.

Our Reviews

What Our Clients Are Saying

Kristi was awesome! She drove an hour in a blizzard to come fix my furnace when I couldn't find anyone else to come help me so that we could have heat during this snowstorm. She was very nice and helpful as well!

M. Murray

Nick & JD were right on time, very nice guys & made quick work of relocating our kitchen gasoline (they had to do some ductwork too to get there!). I really appreciated how fast Church could respond to my appointment request & how easy communication was the entire project. Will be using again, will even try…

K. Peachey

I and my neighbors have used Church Plumbing & Heating for years and are totally loyal to this business because they deliver exactly as promised, efficiently and professionally, and at affordable prices. Recently, we had a seriously blocked kitchen sink, that one workman threw his hands up and said he couldn't fix it, and yet Church…

Q. Martin

Kristi was top notch and provided A1 service. Very professional and pleasant. As always Church Plumbing was able to work around my schedule to accommodate me and complete my services.

T. Bay

This was quite possible the best service call I’ve experienced. JD explained everything and worked with me so I could see how he worked through my radiator issue and we came to find a solution. He also listened and repaired my toilet so much better than the last person we had called out for the same…

D. Dodwell